SLT acoustic logging tool
SLT tool is one main logging tool of CSU series .
The instrument uses a high-power magnetostrictive transmitter transducer, high-temperature attenuation is small; using metal bellows and Acoustic Transmission. cover, to improve the efficiency of sound transmission , reduce direct wave coupling, and the penetration of H2S.
The instrument can be used directly in CSU system, 520 system.
The instrument can also be connected with long-spaced sonic probe.
● temperature: 175℃;
● pressure: 140MPa;
● OD: 92mm;
● speed: 1800 m / h;
● Power requirements: 150Vac ± 10V, 50 ~ 60H, ≈ 80mAac;
250Vac ± 25V, 50 ~ 60H, ≈ 50mAac; (data transmission interface)
● Measuring range: 40 to 198μs/ft;
● difference measurement accuracy: △T In the range of 40 ~ 60us/ft is ±2μs/ft;
△T in the range of 60 ~ 198us/ft is ±3μs/ft;
measuring In the steel casing is 57 ± 1μs/ft;
● Vertical resolution: 600mm;
● laterlog depth: 100mm;
● spacing and distance: 3'-2'-3 '.